Thermowells

Precision pressure-containing thermowells per ASME B40.9 for RTD sensors and thermocouple assemblies. Drilled bar and fabricated construction in 316 SS, 316L, Inconel 600/625, and Hastelloy C-276. Straight, tapered, and stepped shank profiles. Threaded, flanged, and Van Stone connections.

ASME B40.9
Standard
+1200°C
Max Temp (Inconel)
6 alloys
Sheath Materials
PTC 19.3
Wake Freq. Calc
What Is a Thermowell?

Sensor Protection Without Process Shutdown

A thermowell is a closed-end pressure-tight tube, permanently installed in a process pipe or vessel, into which a temperature sensor is inserted. The thermowell separates the sensor from the process fluid — protecting it against corrosion, erosion, flow velocity, and pressure — while allowing the sensor to be removed and replaced without taking the process offline or isolating pressure.

Thermowells are pressure-containing components and must be specified with adequate wall thickness for the rated pressure and temperature. They are also subject to vortex-induced vibration from process flow — requiring wake frequency analysis per ASME PTC 19.3 TW to ensure the natural frequency of the thermowell stem exceeds the vortex shedding frequency at maximum flow velocity.

Thermometrics manufactures thermowells per ASME B40.9 in all standard construction types, materials, and process connections. Matched thermowell-sensor assemblies (sensor + thermowell specified together) ensure correct bore diameter, immersion length, and lag characteristics for your application.

Request a QuoteWake Frequency Info
PROCESS FLUID U Immersion T OAL Connection Head Process Connection Shank Tip Sensor tip PIPE WALL PIPE WALL ASME B40.9 THERMOWELL ANATOMY
Construction Methods

Drilled Bar vs Fabricated

ASME B40.9 recognises two primary thermowell construction methods. Selection is governed by process conditions.

Preferred for High-Pressure Service
Drilled Bar Construction

Manufactured from solid bar stock — the bore is produced by gun-drilling or deep-hole drilling through the full length. No weld seams exist in the pressure zone. Wall thickness is uniform and controlled throughout the immersion length. This construction provides the highest structural integrity and is mandatory per ASME B40.9 for high-pressure service.

No weld seams in pressure-containing zone — eliminates weld defect failure mode
Uniform wall thickness — higher burst pressure rating
Superior fatigue strength — critical for high-flow-velocity vortex environments
Required per ASME B40.9 for pressures above 3000 psi and critical service
Available in all standard materials: 316 SS, 316L, Inconel 600/625, Hastelloy C-276
High pressureHigh velocityCritical servicePower & O&GASME B40.9 preferred
General Purpose / Lower Pressure
Fabricated Construction

Assembled by welding a precision-machined tip onto a tube shank. The tube provides the bore; the tip forms the closed end. Weld integrity is a critical quality characteristic — Thermometrics inspects all fabricated thermowell welds visually and by dye penetrant (PT) per ASME B40.9 requirements. Lower material cost and more economical for longer immersion lengths in lower-pressure service.

Lower cost — economical for standard pressure/temperature service
Available in longer immersion lengths more economically than drilled bar
All welds inspected per ASME B40.9 — PT inspection standard
Suitable for pressures up to 3000 psi in standard service
Wide material availability including 304 SS, 316 SS, 316L
General industrialLower pressureLonger immersionCost-effective
Shank Geometry

Shank Profiles

Shank profile determines the thermowell's wake frequency response, strength, and flow-induced stress characteristics. Selection is part of the ASME PTC 19.3 TW wake frequency calculation.

STRAIGHT
Straight Shank
Constant OD throughout immersion length. Simplest to manufacture. Highest natural frequency for given tip mass. Limited to lower flow velocities — straight shank is more susceptible to vortex resonance than tapered at equivalent immersion depth.
Best for: Low velocity · Short immersion · Standard service
TAPERED
Tapered Shank
OD reduces linearly from root to tip. Heavier root section provides higher moment of inertia and natural frequency. Reduced tip mass lowers flow-induced deflection amplitude. The preferred profile for high flow velocity applications — provides the best combination of strength and wake frequency margin per ASME PTC 19.3 TW.
Best for: High velocity · Long immersion · Critical service
STEPPED
Stepped Shank
Larger OD at root transitions to smaller OD at tip — a discrete step rather than continuous taper. Root section provides high bending stiffness; reduced tip section minimises drag and vortex cross-section. Economical compromise between straight and tapered. Suitable for moderate flow velocity applications.
Best for: Moderate velocity · General process · Cost-sensitive
Process Connection Types

Connection Styles

Connection TypeConstructionTypical Pressure RatingApplication
Threaded — NPTExternal male NPT thread (1/2" to 2" NPT). Screwed into a coupling or boss welded on pipe.Up to Class 600 (1480 psi at 100°F for 316 SS) — pressure/temp rating per ASME B1.20.1Most common. General industrial piping. Easy retrofit installation.
Flanged — ASME B16.5Thermowell welded to flange matching pipe flange rating. Class 150 through Class 2500 available.Class 150 to Class 2500 — full flange pressure class ratingHigh-pressure pipelines, vessels. Allows removal without breaking process connection.
Van Stone (Lap Joint)Thermowell with loose lapped flange (field-rotatable). Thermowell tube slips through flange bore.Same as flanged class selectedWhere bolt-hole alignment must be field-adjusted. Cryogenic service (no socket weld thermal stress).
Weld-In / Socket WeldThermowell root machined with socket or butt weld prep. Welded directly into pipe nozzle.Limited by pipe schedule — no connection fitting rating lossCritical high-pressure service. No threaded connection leak path.
Sanitary Tri-ClampSanitary clamp ferrule. 304 or 316L. Ra ≤ 0.8 µm bore finish standard.Up to 150 psi typicalPharmaceutical, food & beverage, biotech. 3-A compliant available.
Sheath Materials

Available Thermowell Materials

Material selection governs corrosion resistance, maximum operating temperature, and pressure rating. Thermometrics holds bar stock in all standard grades for prompt delivery.

AISI 316 / UNS S31600
316 Stainless Steel
General purpose austenitic SS. Mo addition provides chloride resistance. Standard for most industrial and process applications.
Max continuous: +900°C
AISI 316L / UNS S31603
316L Stainless Steel
Low-carbon variant of 316. Preferred for welded assemblies — eliminates sensitisation and intergranular corrosion risk at welds. Pharmaceutical and nuclear grade standard.
Max continuous: +870°C
UNS N06600 Ni-Cr
Inconel 600
High-temperature oxidation and corrosion resistance. Standard aerospace and heat treating thermowell alloy above 900°C service temperatures.
Max continuous: +1175°C
UNS N06625 Ni-Cr-Mo
Inconel 625
Superior strength and seawater/marine corrosion resistance vs IN600. High-pressure service in O&G and chemical environments.
Max continuous: +980°C
UNS N10276 Ni-Mo-Cr
Hastelloy C-276
Outstanding resistance to strong oxidising and reducing acids, chlorides, and wet chlorine. Chemical processing and flue gas environments.
Max continuous: +1040°C
AISI 304 / UNS S30400
304 Stainless Steel
Cost-effective austenitic SS for non-chloride service. Suitable where 316 Mo addition is not required. Standard for non-critical general use.
Max continuous: +870°C
Standard Configurations

Standard Thermowell Dimensions

Standard ASME B40.9 dimensions. Custom immersion lengths, bore diameters, and shank profiles available to order. All dimensions in millimetres (mm) unless noted.

ModelShank TypeProcess ConnectionRoot OD (mm)Tip OD (mm)Bore Ø (mm)Standard U (mm)Construction
TW-S-NPT-100Straight1/2" NPT16.016.06.35100, 150, 200, 250Drilled Bar
TW-S-NPT-150Straight3/4" NPT19.019.06.35100, 150, 200, 250, 300Drilled Bar
TW-T-NPT-150Tapered3/4" NPT25.412.76.35150, 200, 250, 300, 400Drilled Bar
TW-T-NPT-200Tapered1" NPT31.815.96.35200, 250, 300, 400, 500Drilled Bar
TW-ST-NPT-150Stepped3/4" NPT22.215.96.35150, 200, 250, 300Drilled Bar
TW-T-FL150-300TaperedASME B16.5 CL150 RF25.412.76.35200, 300, 400, 500Drilled Bar
TW-T-FL300-300TaperedASME B16.5 CL300 RF31.815.96.35200, 300, 400, 500Drilled Bar
TW-S-TC-100StraightTri-Clamp 1.5"16.016.06.35100, 150, 200Fabricated
TW-S-TC-150StraightTri-Clamp 2"16.016.06.35150, 200, 250Fabricated
Custom immersion lengths, bore diameters (6.35 mm standard; 4.76 mm and 8.0 mm available), and materials to order. U-lengths above are standard stock; non-standard cut to length with 3–5 day lead time.
ASME PTC 19.3 TW

Wake Frequency Calculation

Flow past a thermowell shank produces alternating vortices — the von Kármán vortex street — at a frequency determined by the Strouhal number, process flow velocity, and shank tip diameter. This is vortex shedding.

If the vortex shedding frequency approaches the thermowell's natural frequency (determined by stem stiffness, length, and tip mass), resonance occurs. Resonant vortex-induced vibration produces cyclic bending stress at the thermowell root that can cause fatigue failure — the single most common thermowell failure mode in process plants.

ASME PTC 19.3 TW (2016) provides the governing calculation procedure. The Strouhal frequency ratio (rf = fS/fn) must remain below 0.8 under maximum flow velocity conditions with a defined safety factor. When the ratio cannot be reduced by shank profile selection alone, shortened immersion length, increased shank OD, or alternative mounting (isolation chamber or thermowell cage) may be required.

Thermometrics can perform or independently review wake frequency calculations on request. Provide process fluid density, dynamic viscosity, maximum flow velocity, pipe internal diameter, and proposed thermowell dimensions.

Request Wake Frequency Review
ASME PTC 19.3 TW Key Parameters
StandardASME PTC 19.3 TW-2016
Strouhal Number (S)0.22 (typical for cylinders)
Shedding freq: fSfS = S·V/dt
Natural freq: fnBeam theory (clamped-free)
Freq ratio rfrf = fS/fn < 0.8 required
Velocity limitAlso calculated per PTC 19.3 TW
Fatigue basisGoodman diagram — material-specific
Required dataρ, µ, Vmax, pipe ID, TW dims
⚠ When Wake Frequency Calc is Mandatory
A wake frequency check is required whenever: process flow velocity exceeds 1 m/s for gas or 0.3 m/s for liquid; immersion length exceeds 300 mm; thermowell operates in a pulsating or fluctuating flow regime; or the service is classified as critical (power generation, O&G, aerospace). ASME B40.9 requires documentation of the calculation in the design record.
Applications

Thermowell Applications by Industry

🛢️
Oil, Gas & Refining
Process pipe, reactor vessel, and heat exchanger temperature measurement. Drilled bar tapered profile for high-velocity flow. H₂S-resistant alloys for sour service.
DRILLED BAR · TAPERED · INCONEL 625 · CL300 FLANGE
⚡
Power Generation
Steam turbine inlet/extraction, feedwater heater, boiler drum, and condenser temperature measurement. API 670 / ASME PTC 19.3 TW wake frequency analysis included.
DRILLED BAR · TAPERED · 316 SS · CL600-2500 FLANGE
💊
Pharmaceutical & Biotech
Bioreactor, steriliser, and clean-in-place (CIP) temperature measurement. Electropolished 316L, Ra ≤ 0.8 µm bore, tri-clamp process connection per 3-A standard.
FABRICATED · STRAIGHT · 316L · TRI-CLAMP · ELECTROPOLISHED
🏭
Chemical Processing
Corrosive process fluid temperature measurement requiring alloy selection beyond 316 SS. Hastelloy C-276 for HCl, HF, and mixed acid service.
DRILLED BAR · HASTELLOY C-276 · SOCKET WELD
FAQ

Thermowell FAQ

A thermowell is a closed-end pressure-tight tube permanently installed in a process pipe or vessel that allows a temperature sensor (RTD or thermocouple) to be inserted into the process fluid without directly contacting it. The thermowell protects the sensor against process pressure, corrosion, erosion, and flow velocity while permitting sensor removal and replacement during process operation without pressure isolation or shutdown. Thermowells are pressure-containing components governed by ASME B40.9 and must be designed and selected with adequate wall thickness for the rated pressure, temperature, and flow conditions.
Drilled bar construction is mandatory per ASME B40.9 for high-pressure service (typically above 3000 psi), high-temperature service, and critical applications where weld integrity cannot be inspected (power generation, O&G, aerospace). Drilled bar has no weld seams in the pressure zone — eliminating the weld-related failure mode that accounts for the majority of thermowell pressure failures. Fabricated construction (welded tip to tube) is acceptable for lower-pressure general industrial service and is more economical for longer immersion lengths. Thermometrics can manufacture both; when in doubt, specify drilled bar.
Wake frequency calculation per ASME PTC 19.3 TW determines whether the vortex shedding frequency at your maximum process flow velocity will approach the thermowell's structural natural frequency. If it does, resonant vortex-induced vibration occurs — producing cyclic stress at the root that causes fatigue failure. A wake frequency check is required whenever flow velocity exceeds approximately 1 m/s for gas or 0.3 m/s for liquid, immersion length exceeds 300 mm, or service is classified as critical. ASME B40.9 requires the calculation to be documented. Thermometrics can perform this calculation as part of your thermowell order — provide fluid density, dynamic viscosity, maximum flow velocity, and pipe internal diameter.
Immersion length (U) — the length of the thermowell shank inserted into the process — should place the thermowell tip in the region of representative process temperature, while maintaining adequate wake frequency margin. For pipes, the standard target is to immerse the tip to the centreline of the pipe, or to 1/3 pipe ID from the opposite wall, whichever results in a shorter immersion. For vessels, tip should reach into the fluid below the minimum process level. U should be the minimum necessary to achieve representative measurement — longer immersion increases deflection amplitude and worsens wake frequency performance. Provide pipe internal diameter, nozzle projection height, and desired tip position when requesting a thermowell, and Thermometrics will calculate the correct U dimension.
Yes. Thermometrics routinely supplies matched assemblies: thermowell specified with bore diameter and immersion length matched to the insertion-length RTD or thermocouple sensor, with the spring-loaded or fixed insertion sensor pre-installed and tested as a unit. Matched assemblies ensure correct element-to-tip depth (critical for accuracy), eliminate field fitment issues, and allow the complete assembly to be certified under a single AS9100D Certificate of Conformance. Specify thermowell process connection, material, and immersion length along with sensor type, element, tolerance, and documentation requirements in your RFQ.
Specify Your Thermowell
Drilled bar and fabricated. All standard materials in stock. Wake frequency analysis available. Same-day response on standard configurations.