(818) 886-3755[email protected]
ISO 9001:2015AS9100D
Request a Quote(818) 886-3755
ISO 9001:2015 · NACE MR0175 Compatible Materials · API 670 Reference

Oil, Gas &
Refining
Temperature Sensors

RTD sensors and thermocouple assemblies engineered for the chemical aggression, high pressure, and wide temperature ranges of upstream, midstream, and downstream oil and gas applications. Hastelloy C-276, Inconel 625, and 316L SS sheath materials. Explosion-proof and weatherproof connection head options.

Temp Range–270 to +1700°C
Max PressureTo customer spec
Sheath — Std316 SS / Inconel 600
Sheath — CorrosiveHastelloy C-276
Sheath — SubseaInconel 625
NACE MR0175Materials Available
Connection HeadSS Weatherproof / XP
QualityISO 9001:2015
Applications

Oil, Gas & Refining Temperature Measurement

🛢️
Wellhead & Production
API 6A · NACE MR0175
Wellhead temperature monitoring, separator vessel skin temperature, and production tubing temperature measurement. H₂S-compatible NACE MR0175 materials required for sour service. Wide ambient range for arctic to desert installations.
TYPE K MIMSHASTELLOY C-276NACE MR0175XP HEAD
🏭
Refinery Process Vessels
API 551 · API 670
Reactor temperature profiling, distillation column tray temperature, fired heater tube skin temperature, and heat exchanger duty monitoring. Multi-point thermocouple assemblies for profile mapping in reactors and columns.
TYPE K/J MIMSMULTI-POINTINCONEL 600THERMOWELL
🔥
Fired Heaters & Furnaces
API 560 · ISO 13705
Radiant tube skin temperature, bridgewall temperature, flue gas temperature, and stack temperature monitoring per API 560. High-temperature Type N or Type K thermocouples. Refractory-anchor designs for direct flame zone exposure.
TYPE K/N/SHIGH TEMPINCONEL 600TO 1300°C
💨
Pipeline & Compressor Stations
ASME B31.8 · API 14E
Natural gas pipeline temperature, compressor inlet/discharge temperature, gas cooler monitoring, and metering station temperature. Thermowells for high-velocity gas flow. RTD sensors for SCADA integration with high accuracy requirement.
PT100 3-WIRE316 SS THERMOWELLWEATHER HEADSCADA
🌊
Offshore & Subsea
NORSOK S-001 · API 17D
Topside process temperature, subsea flowline temperature, and umbilical-mounted sensors for subsea production systems. Inconel 625 for seawater chloride resistance. Pressure-rated assemblies for high-pressure subsea environments.
INCONEL 625CHLORIDE RESISTANTHIGH PRESSUREMIMS
⚗️
Chemical & Petrochemical
NACE MR0175 · ASME
Reactor temperature profiling, heat exchanger monitoring, column temperature mapping, and catalyst bed temperature measurement in petrochemical plants. Hastelloy C-276 for strong acid and chloride environments.
HASTELLOY C-276TYPE K/N/JMULTI-POINTHIGH CORROSION
Sheath Material Selection

Corrosion-Resistant Sheath Materials for O&G Service

Sheath material selection is critical in oil and gas service. Chloride stress corrosion cracking (SCC) of 316 SS, sulfide stress cracking (SSC) of standard alloys in H₂S service (NACE MR0175), and pitting corrosion in offshore environments all require careful material specification.

Sheath MaterialUNSMax TempKey PropertiesO&G Applications
316 Stainless SteelS31600900°C cont.General corrosion resistance, moderate chloride resistanceGeneral process, non-sour, onshore
316L Stainless SteelS31603900°C cont.Low carbon — weld-sensitization resistant, CIP/SIPSour gas caution — verify NACE compliance for H₂S
Inconel 600N066001175°C cont.High temp oxidation resistance, moderate corrosion resistanceFired heaters, process furnaces, high temp reactors
Inconel 625N06625980°C cont.Excellent seawater resistance, pitting/crevice corrosion resistantOffshore topside, subsea, chloride-containing streams
Hastelloy C-276N102761040°C cont.Outstanding resistance to strong acids, oxidizing and reducing acids, chloridesSour crude, HCl, H₂SO₄, chlorinated hydrocarbons
Monel 400N04400480°C cont.Excellent in HF, seawater, reducing acidsAlkylation units (HF service), seawater cooling

For sour service (H₂S-containing streams), consult NACE MR0175/ISO 15156 for material qualification requirements. Hastelloy C-276 and Inconel 625 are generally compliant for sour service. Verify specific alloy and heat treatment condition against NACE tables before specifying.

Recommended Configurations

Standard O&G Sensor Configurations

TMC-TC-K-MIMS-OG
Type K MIMS — General O&G Process
Ungrounded, Inconel 600, –200°C to +1200°C, weatherproof 316 SS head, screw terminal block
TYPE K UNGROUNDEDINCONEL 600WEATHER HEAD
TMC-TC-K-HAST
Type K — Hastelloy C-276, Sour/Corrosive Service
Hastelloy C-276 sheath, ungrounded MIMS, H₂S and chloride resistant, XP head available
HASTELLOY C-276NACE MATERIALSXP HEAD OPT
TMC-TC-N-HT-OG
Type N — Fired Heater / High-Temp Stability
Type N Nicrosil-Nisil, Inconel 600, –270°C to +1300°C, superior drift stability vs Type K above 500°C
TYPE N MIMSINCONEL 600+1300°C MAX
TMC-RTD-OG-3W
PT100 RTD — Pipeline / Metering
PT100 3-wire, IEC 60751 Class B, 316 SS, 4.76 or 6.35 mm OD, for thermowell installation
PT100 3-WIREIEC 60751 CLASS BTHERMOWELL READY
TMC-TC-MULTI-REACTOR
Multi-Point TC Assembly — Reactor Profiling
2–20 Type K junctions, single MIMS sheath, staggered sensing points for bed temperature profile
UP TO 20 JUNCTIONSTYPE K or NCUSTOM SPACING
FAQ

O&G Sensor FAQ

Common technical questions on temperature sensor selection for oil, gas, and refining applications.

Request a Quote
What does NACE MR0175 compliance mean for thermocouple sheaths?
NACE MR0175 / ISO 15156 specifies materials and material conditions that are resistant to sulfide stress cracking (SSC) and other hydrogen-induced cracking mechanisms in H₂S-containing environments. For thermocouple and RTD sheaths in sour service, standard 316 SS is not automatically compliant — the material must meet specific hardness and heat treatment requirements. Inconel 625 (UNS N06625) and Hastelloy C-276 (UNS N10276) are generally listed as compliant for sour service in the as-annealed condition. When specifying sensors for H₂S-containing streams, confirm that all metallic components — including connection head, fittings, and thermowell — meet MR0175 requirements for the specific temperature, pH, and H₂S partial pressure conditions.
When should a thermowell be used instead of direct insertion?
Thermowells are used when the sensor must be replaceable under process conditions (live removal without process shutdown), when the process is at high pressure, when the process fluid velocity would cause excessive vibration or erosion of the sensor sheath, or when the process is chemically incompatible with sensor sheath materials but compatible with the thermowell material. Direct insertion is acceptable for low-pressure, low-velocity, or benign chemical environments where sensor replacement during shutdown is acceptable. API 551 and ASME PTC 19.3 TW provide guidance on thermowell selection, insertion length, and wake frequency calculation to avoid vortex-induced resonance at process flow velocities.
Why use Type N instead of Type K for refinery fired heater service?
Type N (Nicrosil/Nisil) was specifically engineered to eliminate the instability mechanisms that cause Type K drift in long-term high-temperature service. Type K undergoes short-range ordering of the Alumel alloy between 200–600°C, causing a negative EMF drift known as the K-effect, and is susceptible to green rot (preferential oxidation of Chromel) in mildly oxidizing or cyclic oxidizing/reducing conditions above 800°C. Type N alloy compositions eliminate both mechanisms through a more stable crystal structure. In fired heater service where sensors may operate at 900–1100°C continuously for months, Type N demonstrates 3–10× lower drift than Type K over equivalent exposure. The tradeoff is slightly lower Seebeck coefficient (~39 vs ~41 µV/°C) and historically higher material cost.
Engineered for Harsh O&G Environments
Hastelloy, Inconel, and NACE-compatible materials. ISO 9001:2015 certified. Same-day response on standard configurations.