Precision PT100 RTD and thermocouple sensors engineered for bearing temperature monitoring in electric motors, gearboxes, turbines, and industrial rotating equipment. Flat-pack, push-in, and embedded designs. AS9100D certified manufacture with full documentation packages.

PT100/TC
Element Types
–50/+250°C
Std Temp Range
<0.3°C
Accuracy Class A
4 styles
Installation Types
AS9100D
Quality Cert
Predictive Maintenance

Bearing Temperature Is the Primary Early Failure Indicator

Bearing failure is the leading cause of motor and gearbox downtime. Temperature rise above baseline operating conditions is the earliest and most reliable indicator of impending failure — preceding vibration anomalies and acoustic emission by 6 to 72 hours in most failure modes.

Continuous bearing temperature monitoring enables condition-based maintenance, eliminates scheduled downtime from unnecessary preventive replacement, and provides the data needed to characterize lubrication adequacy, misalignment, overloading, and contamination — before catastrophic failure occurs.

6–72 hr
Early warning lead time before failure
10°C Rule
Grease life halves for every 10°C increase above rating
<±0.3°C
PT100 Class A accuracy for trend detection
>70%
Of bearing failures attributable to lubrication issues
Failure Mode Temperature Profile
NORMAL CAUTION CRITICAL Baseline +15°C Rise ALARM Tbase +25°C +50°C +80°C t=0 +6 hr +24 hr
Typical progressive failure profile. Absolute alarm thresholds vary by bearing class, speed, and load. Continuous monitoring captures the gradient — critical for distinguishing transient thermal spikes from progressive deterioration.
Installation Methods

Four Standard Installation Configurations

Sensor geometry is determined by bearing type, housing design, and access constraints. All designs maintain electrical isolation from bearing race and housing to prevent ground loop interference with monitoring instrumentation.

TYPE 01
Flat-Pack / Low-Profile
Element and leads encapsulated in a thin laminated pack — typically 1.0–2.5 mm total thickness. Installs in radial clearance between outer race OD and housing bore. No housing machining required. Spring-loaded versions maintain contact force under thermal cycling.
1.0–2.5 mm thickNo machiningMotorsGearboxes
TYPE 02
Push-In / Cartridge
Cylindrical cartridge sensor inserted through a drilled radial hole in the bearing housing. Spring clip or set screw retention. Tip makes contact with or rests close to the outer race OD. Standard cartridge ODs 4.76 mm (3/16") and 6.35 mm (1/4") for common housing drill sizes.
4.76 / 6.35 mm ODSpring retentionRadial holeHigh vibration
TYPE 03
Embedded / Potted
Element embedded directly in the bearing housing wall during manufacture or retrofit, potted with thermally conductive epoxy. Provides maximum thermal contact, protection from contamination, and lowest profile. Common in aerospace motor applications and custom gearbox housings.
Max thermal contactEpoxy pottedAerospace motorsLow profile
TYPE 04
Surface / Strap Mount
Sensor clamped or strapped to the external surface of the bearing housing OD. Simplest retrofit option — no drilling or machining. Thermal response is slower due to housing wall thermal resistance, but acceptable for low-speed or low-criticality applications where trends, not absolute temperature, are primary.
No machiningRetrofitSlower responseTrend monitoring
Product Configurations

Standard Bearing Sensor Configurations

Custom dimensions, connector types, lead lengths, and sheath materials available on all configurations. Contact engineering for application-specific designs.

Aerospace Grade
TMC-BRG-RTD-FP-AE
Flat-Pack PT100 — Aerospace
Low-profile motor bearing RTD for aerospace actuator and accessory gearbox applications
ElementPT100 (IEC 60751 Class A)
Wiring3-Wire or 4-Wire
Temp Range–55°C to +200°C
Profile1.5 mm typ (custom)
Accuracy±0.3°C at 0°C (Class A)
Lead WirePTFE, AWG 26 stranded
CertificationAS9100D COC, NIST Cal
TMC-BRG-RTD-CI
Cartridge PT100 — Push-In
Spring-loaded cartridge for drilled housing bore, high-vibration industrial motors
ElementPT100 (IEC 60751 Class B)
Wiring3-Wire standard
Temp Range–50°C to +180°C
OD6.35 mm (1/4")
Length25–100 mm (custom)
Sheath304 SS standard
RetentionSpring clip or set screw
TMC-BRG-TC-K-FP
Flat-Pack Type K — High Temp
Type K MIMS thermocouple flat-pack for high-temperature bearing and housing monitoring above RTD limits
ElementType K (IEC 60584 Class 1)
JunctionUngrounded (isolated)
Temp Range–200°C to +600°C
Profile2.0 mm typ
Accuracy±1.5°C or ±0.4% (Class 1)
SheathInconel 600
LeadType KX extension alloy
TMC-BRG-RTD-EMBD
Embedded PT100 — Custom Housing
Potted element assembly for embedding in housing wall during manufacture or precision retrofit machining
ElementPT100 (Class A or Class B)
EncapsulationThermally conductive epoxy
Temp Range–55°C to +200°C
EnvelopeTo customer drawing
LeadPTFE or glass braid
Minimum Order1 unit (prototype)
TMC-BRG-RTD-STRP
Surface / Strap-Mount PT100
External housing surface sensor with spring strap mount — fastest retrofit, no drilling required
ElementPT100 (Class B standard)
MountingStainless spring strap
Temp Range–40°C to +150°C
Housing OD40–250 mm range
Response~15–60 sec (housing-dependent)
IP RatingIP65 with boot seal
TMC-BRG-MULTI
Multi-Point Bearing Array
Multi-element harness for monitoring drive end (DE) and non-drive end (NDE) bearings from a single instrumentation connection point
Elements2, 4, or 6 PT100 sensors
WiringCommon return or individual 3W
ConnectorTerminal block or M12 multipin
Lead LengthCustom — to instrument panel
IdentificationTagged, color-coded leads
ApplicationDrive trains, turbine journals
Sensor Selection

PT100 RTD vs. Thermocouple for Bearing Monitoring

Both sensing technologies are used in bearing monitoring. Selection depends on temperature range, accuracy requirements, wiring constraints, and EMI environment.

ParameterPT100 RTD (4-Wire)Type K Thermocouple
Accuracy (at 100°C)±0.35°C (Class A)±1.5–2.5°C (Class 1–2)
Long-Term StabilityExcellent — <0.1°C/year driftModerate — susceptible to decalibration
Temperature Range–200°C to +600°C–200°C to +1260°C
Response Time (flat-pack)2–10 sec typical1–5 sec typical
EMI/RFI RejectionExcellent (low resistance, 4W)Fair — requires shielded extension
Wiring Complexity3 or 4 conductors required2 conductors (matched alloy)
Lead Wire CostCopper — low costKX alloy extension — higher cost
Cold Junction CompensationNot requiredRequired at instrument
Recommended UseStandard bearing monitoring (most applications)High-temp or fast-response applications

For most electric motor and gearbox bearing monitoring applications, PT100 RTD in 3-wire configuration with Class A element is the standard recommendation. Thermocouple sensors are selected where bearing operating temperature may exceed 300°C or where sub-second response is required.

Reference Data

Typical Bearing Temperature Alarm Thresholds

The values below are general industry reference points. Actual alarm setpoints must be established from baseline commissioning data for the specific machine and operating conditions. Both absolute temperature and rate-of-rise (ΔT/Δt) alarms are recommended.

Bearing/Machine TypeNormal Operating RangeWarning ThresholdAlarm / TripNotes
Anti-friction (rolling element) — standard electric motor40–80°C (housing)90°C or +20°C above baseline100°C or +30°C above baselineIEC 60034-14 guidance; absolute threshold varies with grease rating
Sleeve / journal bearing — general industrial50–80°C (babbitt)90–100°C babbitt110°C babbittBabbitt metal temp limit; alarm at 105–110°C common practice
High-speed turbine journal bearing60–90°C (white metal)100°C110–120°C (emergency trip)API 670 provides specific setpoint methodology for rotating machinery protection
Aerospace motor / actuator bearingDefined by motor specTrating − 20°CTrating − 10°CGrease thermal rating governs; often 125°C or 150°C rated grease
Gearbox bearing — rate-of-rise alarmStable ±2°C+5°C in 15 minutes+10°C in 15 minutesRate-of-rise alarm independent of absolute value — early fault indicator

Source: IEC 60034-14, API 670, ISO 13373. These values are for reference only. Consult OEM documentation and establish baseline for each specific machine installation.

Applications

Bearing Sensor Applications

⚡
Electric Motors
NEMA/IEC frame motors — drive end and NDE bearing monitoring, motor thermal protection. Flat-pack sensors for tight clearance housings.
⚙️
Gearboxes
Input, intermediate, and output shaft bearing monitoring. Multi-point arrays with common instrumentation connection. Oil sump temperature monitoring.
✈️
Aerospace Actuators
Flight control actuator and ECS motor bearing monitoring. AS9100D certified with full documentation package. Low-profile flat-pack for tight envelope actuators.
🔄
Turbines & Compressors
Journal bearing white metal temperature — API 670 compatible. High-vibration environments. Type K thermocouple option for high-temperature journal bearings.
💨
Wind Turbines
Main shaft, gearbox, and generator bearing monitoring. Cold climate ratings to –55°C. Long lead runs to nacelle instrumentation systems.
🏭
Pumps & Fans
Centrifugal and positive displacement pump bearing monitoring. Strap-mount retrofit sensors for installed fleet condition monitoring without shutdown.
🚂
Rail Traction Motors
Traction motor armature and pinion bearing monitoring. Vibration-rated MIMS sensors. Wide temperature range for ambient −40°C cold soak to operational temperatures.
🔬
Test & Development
Bearing endurance test rigs, loaded life test machines, and tribology research. NIST-traceable calibration certificates available for data integrity.
FAQ

Bearing Sensor Questions

Technical questions about bearing temperature sensor selection, installation, and calibration. Contact our engineering team for application-specific guidance.

Request a Quote
What type of temperature sensor is best for bearing monitoring?
PT100 RTD sensors in Class A with 3-wire or 4-wire configuration are the standard recommendation for most bearing monitoring applications. Advantages over thermocouples include superior accuracy (±0.3°C Class A vs ±1.5°C for Type K Class 1), excellent long-term stability with minimal drift, no cold junction compensation requirement at the instrument, and good EMI immunity from motor winding interference. Thermocouples are preferred when bearing operating temperature exceeds approximately 300°C, where PT100 elements begin to lose accuracy, or where sub-second response time is required — such as in endurance testing applications.
What is a flat-pack bearing sensor and how does it install?
A flat-pack bearing sensor encapsulates the sensing element and lead wires in a thin laminated profile — typically 1.0 to 2.5 mm total thickness. The sensor is inserted into the radial clearance gap between the bearing outer race OD and the housing bore, requiring no machining of the housing. Spring-loaded variants use a pre-formed bow in the laminate to maintain contact force under thermal cycling and vibration. The sensor reads outer race temperature rather than babbitt or rolling element temperature directly, with a small offset that must be accounted for in setpoint configuration. Flat-pack installation is fastest and is preferred for retrofit applications or designs where housing modification is not permissible.
How should bearing sensor lead wires be routed to avoid interference?
Route RTD lead wires in shielded twisted-pair cable, with the shield grounded at the instrument (single-point ground) only. Do not ground the shield at the sensor end — this creates a ground loop. Maintain physical separation from motor power cables — minimum 150 mm recommended, more in high-power installations. Where separation is not possible, cross power cables at 90° rather than running parallel. For thermocouples, use matched-alloy extension wire with overall shield. In high-EMI environments (VFD-driven motors), ferrite cores on the lead cable at the instrument input can suppress common-mode noise. Never run sensor wiring in the same conduit as motor power leads.
Can bearing sensors be calibrated in place?
In-situ calibration of installed bearing sensors is not practical — the sensor cannot be brought to a known reference temperature while installed. Two approaches are used: (1) System-level verification — disconnect the sensor leads and inject a known precision resistance (for RTDs) or millivolt signal (for thermocouples) at the instrument terminals to verify the measurement chain from sensor to readout. (2) Periodic replacement — for critical applications, replace sensors on a scheduled interval with fresh NIST-traceable calibrated units. Thermometrics supplies replacement sensors with NIST-traceable calibration certificates. Records of as-found calibration data and replacement history are required for AS9100D traceability under aerospace quality programs.
Ready to Specify Your Bearing Sensor?
Engineering review on all RFQs. AS9100D documentation available. No minimum order quantity.