(818) 886-3755 [email protected] Northridge, CA
AS9100DISO 9001:2015
IEC 60584 · MIMS · Inconel · AS9100D

Custom
Thermocouple
Assemblies

MIMS and conventional thermocouple assemblies in Types K, J, T, N, E, R, S, and B — manufactured to IEC 60584 Class 1 and Class 2 tolerance in Inconel 600, Inconel 625, Hastelloy C-276, and 316 SS sheaths. Any length, any termination. AS9100D quality documentation standard.

Thermocouple Product Summary
8
Thermocouple Types K·J·T·N·E·R·S·B
+1820°C
Max Temperature — Type B
Class 1
IEC 60584-2 — Tightest Standard Tol.
MIMS
Standard Construction — Seamless
NIST
Traceable Cal Certificate Available
AS9100D
COC + Material Certs Standard
Thermocouple Types

All IEC 60584 Types Available

Every standard thermocouple type manufactured in-house to IEC 60584 tolerance — from the general-purpose Type K to noble metal Type R/S SAT reference sensors. Custom alloy combinations and non-standard types on request.

K
CHROMEL (Ni–10%Cr) / ALUMEL (Ni–5%Al–2%Si)
General Purpose — Most Common Type

The world's most-used thermocouple. Wide temperature range, good linearity (~41 µV/°C), and universal instrument support. Subject to short-range ordering (K-effect) in 200–650°C service — Type N is the stability upgrade for long-term furnace applications. Positive leg color: Green (IEC), Yellow (ANSI).

Range–270°C to +1372°C
Sensitivity at 25°C~40.6 µV/°C
IEC Class 1 Tol.±1.5°C or ±0.4%|t|
Recommended SheathInconel 600 above 500°C
Extension WireKX-grade (IEC 60584-3)
J
IRON (Fe) / CONSTANTAN (Cu–45%Ni)
High Sensitivity — Reducing Atmospheres

Higher sensitivity than Type K (~52 µV/°C). Preferred for reducing and vacuum atmospheres where iron is stable but chromium-containing alloys would preferentially oxidize. Iron leg corrodes rapidly above 550°C in air and in wet environments. Limit continuous use in oxidizing atmosphere to ~500°C. Iron leg is magnetic — small Curie point perturbation at 770°C.

Range–210°C to +1200°C
Sensitivity at 25°C~51.7 µV/°C
IEC Class 1 Tol.±1.5°C or ±0.4%|t|
Max Oxidizing Atmosphere+500°C continuous
Extension WireJX-grade
T
COPPER (Cu) / CONSTANTAN (Cu–45%Ni)
Cryogenic & Sub-Zero Applications

The preferred thermocouple for cryogenic, refrigeration, pharmaceutical cold chain, and food processing applications. Stable and well-characterized at sub-zero temperatures. Both alloy legs resist corrosion in moist environments. Copper positive leg limits maximum temperature to +400°C. IEC Class 1 tolerance of ±0.5°C is the tightest fixed tolerance of any standard base-metal type.

Range–270°C to +400°C
Sensitivity at 25°C~40.9 µV/°C
IEC Class 1 Tol.±0.5°C or ±0.4%|t|
Best UseCryogenic, pharma cold chain
Extension WireTX-grade (copper matched)
N
NICROSIL (Ni–14%Cr–1.4%Si) / NISIL (Ni–4.4%Si–0.1%Mg)
Long-Term Stability — K Replacement

Engineered to correct the drift mechanisms in Type K. Silicon additions to both legs stabilize the alloy microstructure and suppress the ordering transformation responsible for K-effect drift. Demonstrates 3–10× less drift than Type K over equivalent service life. Preferred for new furnace installations above 500°C and for AMS 2750F heat treating where calibration interval reduction is desired.

Range–270°C to +1300°C
Sensitivity at 600°C~38.9 µV/°C
IEC Class 1 Tol.±1.5°C or ±0.4%|t|
Drift vs. Type K3–10× less at 500–1300°C
Extension WireNX-grade
E
CHROMEL (Ni–10%Cr) / CONSTANTAN (Cu–45%Ni)
Highest Sensitivity — Low-Level Detection

Type E has the highest Seebeck coefficient (~68 µV/°C at 0°C) of all IEC-standardized thermocouple types — approximately 65% higher than Type K at the same temperature. This makes Type E best suited for detecting small temperature differences, differential temperature measurement, and applications where measurement resolution is critical. Non-magnetic, which is an advantage in some EMI environments. Limited to +1000°C maximum.

Range–270°C to +1000°C
Sensitivity at 0°C~58.7 µV/°C (highest)
IEC Class 1 Tol.±1.5°C or ±0.4%|t|
Best UseHigh-resolution, differential ΔT
Extension WireEX-grade (IEC 60584-3)
R&S
Pt13%Rh/Pt (R) · Pt10%Rh/Pt (S) · NOBLE METAL
SAT Reference — Highest Accuracy

Noble metal platinum-rhodium thermocouples offering the highest accuracy and stability of any IEC-standardized type in oxidizing atmospheres above 600°C. IEC Class 1 tolerance of ±1.0°C at 1000°C. Required for AMS 2750F SAT (System Accuracy Test) sensors and NIST-traceable reference applications. NIST-traceable calibration certificate is standard at Thermometrics for all noble metal shipments.

Range–50°C to +1768°C
Sensitivity at 1000°C~10.5 µV/°C (R), ~10.2 (S)
IEC Class 1 Tol.±1.0°C or ±0.25%|t|
Cal CertificateNIST-traceable — standard
ApplicationSAT reference, AMS 2750F
B
Pt30%Rh (positive) / Pt6%Rh (negative) · NOBLE METAL
Ultra-High Temperature — Above 1600°C

Type B is the only IEC-standardized thermocouple type suitable for continuous service above 1600°C in oxidizing or neutral atmospheres. Both legs contain rhodium, producing near-zero EMF at room temperature — this means Type B cannot distinguish temperatures below approximately 50°C and must not be used below +600°C. Very low sensitivity (~6 µV/°C) requires careful instrument selection. Superior contamination resistance vs. Types R and S due to absence of pure platinum leg.

Useful Range+600°C to +1820°C
Sensitivity at 1000°C~6.1 µV/°C
IEC Class 2 Tol.±3.0°C or ±0.25%|t|
Do Not Use Below+600°C
ApplicationVacuum brazing, ultra-high temp
Custom
NON-STANDARD TYPES · SPECIAL ALLOYS
Type C · W-Re Refractory · Special Alloys

Type C (W5%Re/W26%Re) for vacuum/inert atmospheres to 2315°C. Non-standard alloy pairs for specific industrial requirements. Dual-element redundant assemblies. Multi-point sensor arrays. Assembly-level test jigs. Contact engineering to discuss your specific high-temperature or special-alloy requirement.

Type C Range0°C to +2315°C (vacuum/inert)
W-Re NoteOxidizes catastrophically in air above 260°C
DeliveryContact engineering for lead time
Construction Methods

MIMS vs. Conventional Construction

All Thermometrics thermocouples are available in MIMS (Mineral Insulated Metal Sheath) or conventional (ceramic/fiberglass insulated) construction. MIMS is the standard for industrial, aerospace, and pressure service applications.

RECOMMENDED
MIMS Construction
MINERAL INSULATED METAL SHEATH · SEAMLESS · COMPACTED MgO
METAL SHEATH (Inconel/SS/Hastelloy) TC WIRES MgO INSULATION (compacted)

MIMS thermocouples are manufactured by drawing a seamless metal sheath tube containing thermocouple wire conductors embedded in compacted magnesium oxide (MgO) powder insulation. The drawing process densifies the MgO to >85% theoretical density, locking the conductors in position and providing excellent vibration resistance, pressure integrity, and high electrical insulation resistance (≥100 MΩ at 500 VDC).

Seamless metal sheath — no joints or welds to fail at pressure
Minimum OD 0.5 mm — can be bent, formed, coiled
Vibration-proof: conductors locked in compacted MgO
Insulation resistance ≥100 MΩ at 500 VDC, 23°C
Pressure rated for process applications — up to 700 bar available
Ungrounded, grounded, or exposed junction options
Sheath materials: 304/316 SS, Inconel 600/625, Hastelloy C-276
Conventional Construction
CERAMIC OR FIBERGLASS INSULATED · OPEN WIRE

Conventional thermocouples consist of bare thermocouple wire conductors insulated with ceramic tubes, fiberglass braiding, or PTFE insulation. No outer metal sheath (or a protection tube added separately). Lower cost for basic applications but limited in vibration resistance, minimum bend radius, and pressure compatibility.

Lower cost for non-demanding applications
Ceramic insulator: suitable up to +1400°C
Fiberglass: suitable to +480°C continuous
PTFE insulation: flexible, suitable to +260°C
Exposed junction gives fastest response time
Not suitable for pressure, vibration, or corrosive media without protection tube
Common for TUS load sensors, research, and furnace atmosphere profiling
Sheath Materials

Standard MIMS Sheath Options

Sheath material selection is determined by process temperature, atmosphere chemistry, and mechanical requirements. Thermometrics stocks standard MIMS sheath materials and can source special alloys on request with mill certification.

AlloyUNSMax ContinuousKey PropertiesPrimary Application
304 SSS30400900°C (oxidizing)General purpose, cost-effective, non-magnetic option availableGeneral industrial, HVAC, low-pressure service
316 SSS31600900°CImproved chloride and pitting corrosion resistance vs. 304Standard process, mild corrosive environments
316L SSS31603900°CLow carbon — resists weld sensitization, FDA/3-A sanitaryPharmaceutical, food processing, CIP/SIP
Inconel 600N066001175°COutstanding high-temperature oxidation resistance, Ni-Cr alloyFurnace, heat treating, aerospace, high-temp TC
Inconel 625N06625980°CH₂S and seawater resistant, high strength, NACE MR0175 compatibleSour service, subsea, O&G, marine
Hastelloy C-276N102761040°CExceptional resistance to oxidizing and reducing corrosion, acids, chloridesChemical processing, chloride media, acid service
Incoloy 800H/HTN08810/N088111100°CHigh-temperature creep strength and oxidation resistanceHigh-temperature furnace, petrochemical reformers
Custom AlloyPer requestPer alloyTitanium, Duplex, SMO 254, platinum-clad — on requestContact engineering for non-standard sheath requirements
Junction Types

Grounded, Ungrounded & Exposed Junctions

For MIMS thermocouples, three junction styles are available — each with different response time, electrical isolation, and application suitability characteristics.

WELD · SHEATH CONTACT
Grounded Junction

The welded junction is in direct contact with the sheath tip. Fastest response time of the three MIMS styles — typically 25–50% faster than ungrounded. The electrical connection to the sheath means ground loops can occur in multi-point systems with common ground instrumentation. Use when response time is critical and electrical isolation is not required.

FAST RESPONSE · NOT ELECTRICALLY ISOLATED · SINGLE-POINT PREFERRED
WELD · MgO GAP · ISOLATED
Ungrounded Junction

The welded junction is electrically isolated from the sheath by a thin layer of compacted MgO powder between the junction and the sheath tip. Electrically isolates the measurement circuit from the process and sheath — eliminates ground loops in multi-point systems. Standard construction recommendation for most industrial MIMS thermocouple applications. Slightly slower response than grounded due to the MgO thermal mass at the tip.

INDUSTRY STANDARD · ELECTRICALLY ISOLATED · MULTI-POINT SYSTEMS
BARE WELD · DIRECT CONTACT
Exposed Junction

The thermocouple wires extend beyond the sheath tip and are welded together as a bare junction directly exposed to the measured medium. Provides the absolute fastest response time — typically T63 <100 ms in flowing gas. Not suitable for corrosive or pressurized processes. Used in gas temperature measurement, AMS 2750F TUS load sensors, and aerodynamic research probes where response speed is paramount.

FASTEST RESPONSE · GAS MEASUREMENT · TUS LOAD SENSORS · NON-CORROSIVE ONLY
Standard Configurations

Catalog Thermocouple Assemblies

Standard configurations available from stock or short lead time. Custom lengths, ODs, and terminations on request — no minimum order on custom dimensions. All ship with Certificate of Conformance and material certifications standard.

TMC-TC-K-IN600-CL1
Type K — Inconel 600, Class 1
General purpose · Furnace · Aerospace
TypeK · Chromel/Alumel
ConstructionMIMS, ungrounded junction
SheathInconel 600 (N06600)
OD Options1.6 / 3.18 / 4.76 / 6.35 mm
ToleranceClass 1 · ±1.5°C or ±0.4%|t|
Range–200°C to +1260°C
DocumentationCOC standard; NIST cal on request
Full Specs →
TMC-TC-N-IN600-CL1
Type N — Inconel 600, Class 1
Long-term stability · AMS 2750F preferred
TypeN · Nicrosil/Nisil
ConstructionMIMS, ungrounded junction
SheathInconel 600 (N06600)
ToleranceClass 1 · ±1.5°C or ±0.4%|t|
Stability3–10× less drift than Type K
Range–270°C to +1300°C
Full Specs →
TMC-TC-K-IN625-MIMS
Type K — Inconel 625, Sour Service
Oil & gas · NACE MR0175 · H₂S environments
TypeK · Chromel/Alumel
ConstructionMIMS, ungrounded junction
SheathInconel 625 (N06625)
Sour ServiceNACE MR0175 compatible sheath
Range–200°C to +980°C
ToleranceClass 2 standard, Class 1 available
Full Specs →
TMC-TC-T-316L-PHARMA
Type T — 316L SS, Pharma Grade
Cryogenic · Cold chain · Lyophilizer validation
TypeT · Copper/Constantan
Sheath316L SS (S31603)
ToleranceClass 1 · ±0.5°C below 125°C
Range–270°C to +400°C
Cal Points–80/–40/0/+25°C available
DocumentationNIST cal cert + FDA material stmt
Full Specs →
TMC-TC-R-NOBLE-SAT
Type R — Noble Metal SAT Reference
AMS 2750F SAT · NADCAP · NIST cal standard
TypeR · Pt13%Rh / Pt
ToleranceClass 1 · ±1.0°C or ±0.25%
Range–50°C to +1768°C
CalibrationNIST-traceable cert — standard
ApplicationAMS 2750F SAT sensor
DocumentationCOC + NIST cal + uncertainty stmt
Full Specs →
TMC-TC-CUSTOM
Custom Configuration
Any type · Any length · Any termination
TypeAny IEC 60584 type; Type C available
OD0.5 mm to 12.7 mm standard
LengthAny insertion length — no minimum
TerminationBare leads, TC connector, terminal head
Lead TimeStandard configs: days. Custom: contact eng.

Specify Your Thermocouple Assembly