Pharma &
Biotech
Temperature Sensors

Precision PT100 RTD and thermocouple sensors for GMP pharmaceutical and biotech manufacturing. NIST-traceable calibration certificates, material certifications, and complete calibration data packages for IQ/OQ/PQ validation protocols. 316L SS and Hastelloy wetted surfaces. ISO 9001:2015 certified manufacture.

Pharma Specification Compliance
Material — Wetted316L SS / Hastelloy C-276
Surface Finish≤ 0.8 µm Ra (32 µin) standard
Element StandardIEC 60751 Class A / Class B
CalibrationNIST-Traceable Certificate
Quality SystemISO 9001:2015 Certified
Autoclave Range121°C / 134°C standard
Lyophilizer RangeDown to –80°C
Cleaning (CIP/SIP)Steam and chemical compatible
GMP Applications

Pharmaceutical Temperature Monitoring Applications

Temperature is a Critical Process Parameter (CPP) across all unit operations in pharmaceutical manufacturing. Accurate, validated, NIST-traceable measurement is required for 21 CFR Part 211 cGMP compliance and regulatory submissions.

🧫
Autoclave / Sterilization
EN 13060 · HTM 2010 · 21 CFR Part 211
Steam sterilization cycle validation requires multiple temperature sensors distributed throughout the load. Sensors must survive repeated 121°C (gravity) and 134°C (prevacuum) cycles with steam penetration and chemical cleaning. NIST calibration required for cycle qualification.
TYPE T RTD or TCNIST CAL316L SS±0.3°C
❄️
Lyophilization (Freeze Drying)
USP <1229.2> · ICH Q8
Lyophilizer shelf and product temperature monitoring across the full freeze-dry cycle: –80°C freeze to +40°C drying. Shelf temperature uniformity mapping per 21 CFR. Type T thermocouples preferred for cryogenic accuracy; PT100 for precision shelf control temperature.
TYPE T (–80°C min)PT100 CLASS ANIST CALFINE WIRE
🧪
Bioreactors & Fermenters
21 CFR Part 211 · Annex 11
Bioreactor temperature control — typically 25–40°C for mammalian cell culture, 28–37°C for microbial fermentation. Sensors must be sterilizable, biocompatible, and CIP/SIP compatible. Sanitary hygienic fittings — tri-clamp or DIN 11851.
PT100 4-WIRE316L SSTRI-CLAMPCIP/SIP
🏭
Cleanroom HVAC & Environmental
ISO 14644 · EU GMP Annex 1
Cleanroom temperature and humidity monitoring for ISO 5 through ISO 8 environments. Temperature sensors for HVAC supply/return air, room ambient, and critical zone monitoring per EU GMP Annex 1 continuous environmental monitoring requirements.
PT100 3-WIRE304 SSDUCT MOUNTNIST CAL
💊
Tablet Coating & Granulation
21 CFR Part 211.68
Inlet and outlet air temperature for fluid bed granulators and tablet coating pans. Product temperature monitoring for endpoint determination. Exhaust air temperature for spray drying applications. High-velocity process air environments.
TYPE K or PT100HIGH VEL AIR316 SS
💉
Cold Chain & Stability Storage
ICH Q1A · USP <1079>
Refrigerated (+2 to +8°C), frozen (–20°C), and ultra-cold (–70 to –80°C) storage temperature monitoring for drug substance and drug product. Stability chamber profiling and validation. Continuous monitoring with alarm capability per ICH Q1A.
PT100 or TYPE T–80°C RATEDNIST CAL4-WIRE
Recommended Products

Sensors for Pharmaceutical Applications

TMC-RTD-SAN-316L
Sanitary PT100 RTD — Tri-Clamp / DIN 11851
316L SS, ≤0.8 µm Ra, CIP/SIP compatible, IEC 60751 Class A
PT100 CLASS A316L SSTRI-CLAMP±0.3°CNIST CAL
TMC-RTD-CRYO-T
Cryogenic PT100 — Lyophilizer / Cold Storage
–200°C to +200°C, 4-wire, Class A, PTFE leads, NIST calibration
PT100 4W CLASS A–200°C MINPTFE LEADNIST CAL
TMC-TC-T-CRYO
Type T Thermocouple — Lyophilizer / Autoclave
–270°C to +400°C, IEC 60584 Class 1, MIMS ungrounded, NIST calibration
TYPE T CLASS 1MIMS UNGROUNDED±0.5°CNIST CAL
TMC-RTD-DUCT-HVAC
Duct / Averaging RTD — Cleanroom HVAC
PT100 averaging element, 304 SS, multiple sensing lengths, NIST calibration
PT100 AVERAGING304 SSDUCT INSERTNIST CAL
TMC-RTD-MULTIPOINT
Multi-Point RTD Array — Stability Chamber / Autoclave
2–12 elements per assembly, PT100 Class A, individual NIST cal certs per element
2–12 ELEMENTSINDIVIDUAL NIST CALCLASS A
Full RTD Sensor Catalog Thermocouple Catalog
Validation Documentation

Documentation for IQ/OQ/PQ Validation

Thermometrics provides the calibration data and quality documentation required to support sensor qualification as part of Installation Qualification (IQ), Operational Qualification (OQ), and Performance Qualification (PQ) protocols.

Standard — All Shipments
Certificate of Conformance
Signed COC confirming sensor conforms to purchase order specification and applicable IEC/ASTM standards. Includes part number, serial/lot, date of manufacture, and authorized signatory.
Standard — All Shipments
Material Certifications
Mill certifications for all sheath and wetted metallic materials. Includes heat/lot number, chemical composition, and mechanical properties per ASTM/EN material specifications. Supports material traceability requirement of 21 CFR Part 211.
On Request
NIST-Traceable Calibration Certificate
Individual calibration certificate per sensor with measured resistance (RTD) or EMF (TC) values at 3–5 calibration points, comparison to nominal values, uncertainty statement, and NIST traceability chain. Required for OQ sensor qualification.
On Request
Calibration Data Table (Spreadsheet)
Electronic calibration data in CSV/Excel format for multi-element arrays. Provides as-found resistance or EMF values at each calibration setpoint for all sensors in the assembly. Supports electronic batch record systems (21 CFR Part 11).
On Request
Calibration Uncertainty Statement
Expanded uncertainty (k=2, 95% confidence) for each calibration point, calculated from the NIST reference standard uncertainty, resolution, repeatability, and stability components. Required for GUM-compliant measurement uncertainty analysis.
On Request
Special Process Certifications
Electropolish certification, passivation per ASTM A967, surface roughness measurement report (Ra), or other special process documentation as required by customer specification or supplier qualification audit.
FAQ

Pharma Temperature Measurement FAQ

Technical questions on pharmaceutical temperature sensor selection, calibration, and GMP compliance.

Request a Quote
What surface finish is required for pharmaceutical-grade RTD sensors?
The 3-A Sanitary Standards (3-A SSI) specify a wetted surface finish of ≤0.8 µm Ra (32 µin Ra) for product-contact surfaces, which is the pharmaceutical industry standard. EHEDG guidance and EU GMP Annex 1 reference similar values. For critical aseptic applications, ≤0.4 µm Ra (16 µin) electropolished finishes are often specified. Thermometrics provides surface roughness measurement reports on request, with electropolish certification as an optional process. Standard catalog products use ≤0.8 µm Ra 316L SS sheath.
How often should pharmaceutical process temperature sensors be recalibrated?
21 CFR Part 211.68 requires that instruments used for monitoring critical process parameters be calibrated at scheduled intervals — but does not prescribe a specific interval. Industry practice is typically annual recalibration for PT100 RTD sensors in pharmaceutical service, with more frequent intervals (6-monthly) for sensors in autoclave or CIP/SIP cycling service due to thermal cycling stress. Calibration intervals should be established based on historical drift data and risk assessment. NIST-traceable as-found and as-left calibration data must be documented. Thermometrics supplies calibrated replacement sensors to support swap-and-recertify programs.
Can PT100 sensors survive repeated autoclave cycles?
Yes, with appropriate construction. MIMS-style PT100 sensors with compacted MgO insulation, 316L SS seamless sheath, and hermetically sealed tip are steam-autoclave compatible for hundreds of standard cycles. Critical design factors: the seal at the sheath tip and lead exit point must be hermetic — steam ingress into the insulation causes catastrophic resistance increase. Lead wire must be rated for repeated exposure to 134°C saturated steam. Glass-braid or PTFE-jacketed leads are common. Avoid PVC-jacketed leads in autoclave service. Thermometrics designs autoclave-grade sensors for this service and can provide cycle-count validation data on request.
What sensor configuration is recommended for lyophilizer shelf temperature monitoring?
Lyophilizer shelf temperature is typically monitored with PT100 RTD sensors embedded in the shelf fluid channels (for shelf control temperature) and Type T thermocouples for product temperature during cycle development. PT100 4-wire Class A is recommended for shelf temperature due to superior accuracy and stability at the –40 to –50°C shelf setpoints typical of primary drying. Type T is preferred for product temperature probes because its accuracy is best in the cryogenic range (–200 to +400°C) and fine-wire Type T probes (0.1 mm wire) have very low thermal mass for accurate product temperature measurement during lyophilization cycle development per FDA guidance.
NIST-Traceable Calibration on Every Order