Thermocouple assemblies and RTD sensors for aerospace heat treating, atmosphere furnace processing, and industrial metal treatment — manufactured to support AMS 2750F pyrometry requirements and NADCAP audit documentation. Type K, N, R, and S available in Inconel sheaths with Class 1 tolerance.
AMS 2750F (Pyrometry) is the SAE Aerospace Material Specification that governs temperature measurement and control in aerospace heat treating processes — including annealing, aging, solution treating, stress relieving, brazing, and precipitation hardening of aerospace alloys.
The standard defines five furnace types (Type A through E) based on temperature uniformity tolerance, and establishes requirements for thermocouple type, calibration frequency, temperature uniformity surveys (TUS), and system accuracy tests (SAT). NADCAP audits verify compliance with AMS 2750F for heat treating suppliers to aerospace primes.
Thermometrics supplies thermocouples that meet the tolerance, calibration, and documentation requirements for AMS 2750F applications. Each thermocouple is supplied with a Certificate of Conformance confirming IEC 60584-2 tolerance class, and NIST-traceable calibration data is available on request for SAT and load sensor qualification.
| TC Type | Alloys | IEC Class | Tolerance at 1000°C | AMS Use Case |
|---|---|---|---|---|
| KChromel/Alumel | –200 to +1260°C | Class 1 | ±4.0°C | General, control, load TCs below 1100°C |
| NNicrosil/Nisil | –270 to +1300°C | Class 1 | ±4.0°C | Preferred over K for long-term stability, minimal drift |
| RPt13%Rh/Pt | –50 to +1768°C | Class 1 | ±1.0°C* | SAT reference, precision, high-temp furnace |
| SPt10%Rh/Pt | –50 to +1768°C | Class 1 | ±1.0°C* | SAT reference, NIST traceable calibration reference |
| BPt30%Rh/Pt6%Rh | +600 to +1820°C | Class 2 | ±3.0°C | Ultra-high temp vacuum/brazing furnaces above 1600°C |
*Noble metal Class 1 tolerance: ±1.0°C or ±[1+0.003(t–1100)]% — whichever is greater. Class 1 required for SAT sensors in most AMS 2750F furnace classes.
Type selection for heat treating applications is driven by maximum process temperature, atmosphere (oxidizing, reducing, vacuum, inert gas), required long-term stability, and AMS 2750F furnace class. Thermometrics stocks all standard types in MIMS construction.
The most widely used thermocouple type in heat treating. Good sensitivity (~41 µV/°C), broad temperature range, and wide instrument availability. Susceptible to the "K-effect" — short-range ordering between 200–600°C causing negative EMF drift in long-term service. Calibration intervals per AMS 2750F account for this drift mechanism.
Engineered as the long-term stability upgrade to Type K. The Nicrosil/Nisil alloy system was specifically formulated to eliminate the short-range ordering transformation responsible for Type K drift above 300°C. Demonstrates 3–10× less drift than Type K over equivalent service life — reducing required calibration frequency and improving process consistency. Preferred for new furnace installations above 500°C.
Platinum-rhodium noble metal thermocouples provide the highest accuracy and long-term stability of any base-metal or noble-metal type in oxidizing atmospheres. Required for SAT (System Accuracy Test) reference sensors in many AMS 2750F furnace classes. Calibration traceability to NIST ITS-90 is straightforward due to inherent stability. Higher material cost than base metals — typically reserved for SAT and control circuits.
Type B is uniquely suited for ultra-high temperature furnace applications in vacuum or inert gas atmospheres above 1600°C — vacuum brazing furnaces, high-temperature solution treating of refractory alloys, and ceramic sintering. Very low sensitivity (~6 µV/°C) and near-zero EMF at room temperature — requires careful instrument setup. Not suitable for reducing atmospheres.
Type J has high sensitivity (~52 µV/°C) and good performance in reducing and vacuum atmospheres below 750°C where Type K would oxidize preferentially. Common in older furnace installations. The iron positive leg oxidizes rapidly above 550°C in air — maximum continuous use in oxidizing atmosphere is 500°C. For new installations above 500°C in oxidizing atmosphere, Type K or N is preferred.
Tungsten-rhenium thermocouples achieve the highest temperature measurement range of any standardized type — to 2315°C in vacuum or inert gas. Required for vacuum sintering, crystal growing, and refractory metal processing. Critical limitation: tungsten oxidizes catastrophically above 260°C in air — must never be exposed to oxygen or moisture at elevated temperature. Brittle at room temperature after high-temperature service.
Solution treating, aging, and annealing of titanium, aluminum, and nickel superalloys per AMS specifications. NADCAP supplier support documentation available.
Carburizing, nitriding, carbonitriding, and neutral hardening in controlled atmosphere furnaces. Sheath material selected for atmosphere compatibility — Inconel 600 for carburizing, 304 SS for neutral.
Immersion temperature measurement in molten salt quench and austempering baths. Inconel 600 sheath resists molten salt corrosion. MIMS construction provides pressure integrity against bath agitation.
Vacuum brazing, vacuum annealing, and vacuum hardening. Type R/S for precision control circuits. Type B above 1600°C. Type C for refractory metal processing to 2315°C.
Low-temperature tempering (150–700°C) and stress relieving of steel and stainless steel. Type K Class 1 or Type N for maximum measurement consistency across multi-zone furnaces.
Multi-point load TCs for TUS qualification per AMS 2750F. Supplied in sets with individual calibration certificates. Special limits of error (SLE) wire grade available for tightest tolerance.
Reference thermocouples for SAT comparison against control and recording thermocouples per AMS 2750F paragraph 3.4. Noble metal Type R or S with current calibration certificate and uncertainty statement.
Fast-response thermocouples for surface temperature measurement during induction hardening — exposed junction or small OD MIMS for sub-second response in rapidly cycling applications.
Stocked configurations for common heat treating sensor requirements. NIST-traceable calibration data available on request. Sets of matched TCs available for TUS applications.
Type K, N, R, S in Inconel 600 sheath. Class 1 tolerance. NIST cal available. TUS sensor sets. NADCAP documentation support.