A practical engineering guide to selecting between RTD (PT100/PT1000) and thermocouple sensors — covering accuracy, temperature range, response time, vibration, cost, and application fit.

Head-to-Head: RTD vs. Thermocouple

ParameterRTD (PT100 / PT1000)Thermocouple (Types K, J, N…)
Operating PrincipleResistance change with temperature (IEC 60751)Seebeck EMF voltage (IEC 60584)
Accuracy (typical best)Class AA: ±0.10°C at 0°C — highest standard accuracyClass 1: ±1.5°C (Type K) — inherently less accurate
Temperature Range–200°C to +850°C (sheathed PT100)–270°C to +1820°C depending on type; TC covers higher temps
Long-Term StabilityExcellent — platinum drift <0.1°C/year typicalGood to moderate — base metals drift under thermal cycling
Response TimeModerate — higher thermal mass than exposed TC junctionFast (exposed junction) — T63 <100 ms possible
Vibration ResistanceMIMS RTD — excellentMIMS TC — excellent
Lead Resistance EffectMust use 3 or 4-wire measurement; significant with 2-wireNo lead resistance issue — mV signal
Self-HeatingYes — I²R heating; <0.1°C in still air with 1 mANone — TC is a passive EMF source
Reference JunctionNot required — RTD is absolute measurementRequired — cold junction compensation (CJC) critical
CostHigher — platinum element and precision windingLower — base-metal alloys are inexpensive
Recommended forBelow 600°C where accuracy matters: pharma, food, lab, processAbove 600°C or where response speed, vibration, or cost drives
Use an RTD When…
Temperature is below 600°C and accuracy is the priority. The application requires long-term stability without periodic recalibration. You need IEC 60751 Class AA or A tolerance (±0.1–0.15°C). The application is pharmaceutical, food, metrology, or laboratory. Process temperature measurement where 4-wire or 3-wire wiring is feasible.
Use a Thermocouple When…
Temperature exceeds 600°C — RTD platinum element degrades above this. Very fast response is needed (exposed junction TC). The environment involves high vibration (MIMS TC is robust). Cost is the dominant constraint for large sensor counts. Reducing, vacuum, or high-pressure atmospheres where TC sheath alloy selection is available.

Not Sure Which to Specify?

Our applications engineers will recommend the right sensor type, tolerance class, and sheath material for your application.