IEC 60584 Type E — Thermocouple Data
Positive LegChromel (Ni-10%Cr)
Negative LegConstantan (Cu-45%Ni)
Full Range–270°C to +1000°C
Practical Range–200°C to +900°C
Seebeck Coefficient~58.7 µV/°C at 0°C; ~68 µV/°C peak
Class 1 Tolerance±1.5°C or ±0.4%|t|
Class 2 Tolerance±2.5°C or ±0.75%|t|
Class 1 IEC Range–40°C to +800°C
Class 2 IEC Range–40°C to +900°C
Color Code (IEC)Purple (+) / White (–)
Color Code (ANSI)Purple (+) / Red (–)
Standard SheathInconel 600 or 316 SS to 900°C
ConstructionMIMS (standard) or conventional; ungrounded, grounded, or exposed junction
DocumentationAS9100D COC + material certs standard; NIST-traceable cal cert on request
Application Notes
Type E has the highest Seebeck coefficient of all IEC 60584-standardized thermocouple types — approximately 65% higher than Type K at equivalent temperatures. This makes it the preferred choice wherever measurement resolution or small ΔT detection is critical. Both alloy legs are non-magnetic, giving Type E an advantage where magnetic interference could affect measurement. Temperature limited to +1000°C maximum.