IEC 60584 Type J — Thermocouple Data
Positive LegIron (Fe)
Negative LegConstantan (Cu-45%Ni)
Full Range–210°C to +1200°C
Practical Range–200°C to +500°C oxidizing / to +750°C reducing
Seebeck Coefficient~51.7 µV/°C at 25°C
Class 1 Tolerance±1.5°C or ±0.4%|t|
Class 2 Tolerance±2.5°C or ±0.75%|t|
Class 1 IEC Range–40°C to +750°C
Class 2 IEC Range–40°C to +1200°C
Color Code (IEC)Black (+) / White (–)
Color Code (ANSI)White (+) / Red (–)
Standard Sheath316 SS to 500°C; Inconel 600 in inert/reducing atmosphere
ConstructionMIMS (standard) or conventional; ungrounded, grounded, or exposed junction
DocumentationAS9100D COC + material certs standard; NIST-traceable cal cert on request
Application Notes
Iron positive leg offers higher sensitivity than Type K but corrodes rapidly in oxidizing atmospheres above 550°C due to iron oxide formation. Iron is also magnetic — a perturbation occurs at the Curie point (~770°C). Limit continuous use in air to 500°C. For new installations above 500°C in oxidizing atmospheres, Type K or N is preferred. Well-suited for reducing and vacuum environments where chromium-bearing alloys would oxidize preferentially.